| Measurement and Generation Capability |
| Primary application | Routine loop checks, commissioning and basic troubleshooting | Maintenance, commissioning and documented calibration of process instruments | High-accuracy field verification, laboratory support and Multifunction Calibration
|
| DC voltage measurement and sourcing | Measurement: typically 0 to 30 V DC Sourcing: typically 0 to 10 V DC | Measurement: typically 0 to 30 V DC Sourcing: typically 0 to 10 V DC | Measurement: typically 0 to 30 V DC Sourcing: typically 0 to 20 V DC |
| DC current measurement and sourcing | Measurement and sourcing: typically 0 to 24 mA | Measurement and sourcing: typically 0 to 24 mA | Measurement and sourcing: typically 0 to 24 mA, with improved resolution and accuracy |
| Loop power supply | Nominal 24 V DC loop power; suitable for standard 4–20 mA transmitters | Nominal 24 V DC loop power; often includes simultaneous mA measurement | Nominal 24 V DC loop power with regulated output and selectable current limits |
| Resistance measurement and simulation | Typically 0 to 400 Ω measurement; basic RTD simulation | Typically 0 to 4 kΩ measurement; wider RTD simulation coverage | Typically 0 to 4 kΩ or higher; improved accuracy for resistance and RTD work |
| RTD support | Common industrial RTDs such as Pt100; usually 2-wire or 3-wire connection | Common Pt, Ni and Cu RTDs; commonly supports 2-wire, 3-wire and 4-wire connections | Broad RTD library with 2-wire, 3-wire and 4-wire measurement capability |
| Thermocouple support | Usually selected thermocouple types such as J, K and T | Commonly supports J, K, T, E, R, S, B and N thermocouples | Broad thermocouple coverage with cold-junction compensation and higher accuracy |
| Frequency and pulse functions | Basic frequency measurement, commonly up to 10 kHz | Frequency measurement and sourcing, commonly up to 10 kHz; pulse counting may be included | Frequency, pulse and switch-test functions with configurable thresholds |
| Pressure measurement | Usually requires an external pressure module or test pump | Compatible with external pressure modules covering vacuum through high pressure | Supports interchangeable pressure modules with multiple ranges and higher accuracy |
| Accuracy, Resolution and Environmental Performance |
| Typical DC mA accuracy | Approximately ±0.05% of reading or better | Approximately ±0.05% of reading or better, depending on range | Approximately ±0.02% of reading or better on selected ranges |
| Typical voltage accuracy | Approximately ±0.05% of reading or better | Approximately ±0.03% of reading or better | Approximately ±0.015% of reading or better on selected ranges |
| Resolution | Commonly 1 µA for current and 1 mV for voltage | Commonly 1 µA for current and 0.1–1 mV for voltage | Commonly 0.1 µA for current and 0.01–0.1 mV for voltage |
| Operating temperature | Typically 0 to 50 °C | Typically −10 to 50 °C | Typically −10 to 50 °C; verify temperature coefficients for precision work |
| Ingress and impact protection | Rugged handheld enclosure; protection level varies by model | Rugged enclosure, protective holster and field-replaceable leads are commonly available | Rugged enclosure with enhanced sealing; confirm the specified IP rating before outdoor use |
| Electrical safety category | Often rated CAT II or CAT III, depending on terminal and operating voltage | Often rated CAT III for industrial measurement circuits; verify the exact rating | Typically designed for industrial environments with documented overvoltage protection |
| Communication, Documentation and Usability |
| HART communication | Usually not included; external communicator may be required | Often available for basic HART device configuration and loop testing | Often available, sometimes with advanced device diagnostics and communication support |
| Foundation Fieldbus support | Not normally included | Available only on selected configurations; check segment and power requirements | May be available as an optional communication function |
| Calibration documentation | Manual recording or simple measurement display | As-found/as-left results, test points, pass/fail limits and technician identification | Detailed electronic records, custom procedures, audit trails and automated reporting |
| Data storage | Limited or no internal storage | Typically stores hundreds to thousands of readings or test results | Typically supports extensive internal memory and export to a computer or calibration database |
| Display and controls | Monochrome or basic color display with direct function keys | Color display, guided menus and dedicated source/measure controls | High-contrast color display, trend views, configurable menus and guided procedures |
| Remote operation | Usually not available | May support USB or wireless data transfer | May support USB, Bluetooth or Wi-Fi data transfer, subject to local security policies |
| Practical Buying Criteria |
| Typical battery endurance | Approximately 10–20 hours of normal measurement or sourcing | Approximately 10–18 hours, depending on display, loop power and communication use | Approximately 8–16 hours; rechargeable battery systems are common |
| Power options | Replaceable alkaline batteries are common | Replaceable or rechargeable batteries; external charger may be supplied | Rechargeable battery pack with AC adapter and field charging options |
| Connection flexibility | Basic banana terminals and test leads | Banana terminals, thermocouple connectors, RTD leads and pressure-module interface | Multiple isolated terminals, pressure-module interface and interchangeable accessories |
| Best fit for global buyers | Low purchase cost, simple operation and routine 4–20 mA maintenance | Balanced capability for plants requiring traceable documentation and broad process coverage | Highest capability for organizations prioritizing accuracy, automation and multi-technology support |
| Points to verify before purchase | Required signal types, loop-power capability, safety rating, local service and spare leads | Pressure-module compatibility, HART functions, software language, calibration certificates and export formats | Uncertainty specification, temperature coefficient, accreditation requirements, communication protocols and total ownership cost |
| Specification note | Values shown are representative capability ranges for comparing process-calibrator classes, not guaranteed specifications for a particular instrument. Always confirm the manufacturer’s datasheet, calibration uncertainty, safety approvals, regional power requirements and traceability documentation before purchase. |