    Description:
    HSIN6800 automatic pressure calibration system is a newly developed pressure sensor calibration and screening system by HSIN. The system uses multiple sensor calibration technologies, and can calibrate multiple pressure sensors at once. It can truly achieve full automatic batch verification of pressure sensors, eliminate errors caused by manual operation, reduce labor intensity of operators, and improve work efficiency. At the same time, HSIN6800 is also capable of testing, calibrating, and calibrating pressure related equipment such as pressure gauges, pressure transmitters, pressure switches, and differential pressure gauges. It is mainly applicable to industries such as sensor manufacturing, measurement institutes, military measurement units, scientific research institutes, etc.
    6800 (1)85s
    Strains 6800 (2)tqg
    Features:
    1.The HSIN6800 pressure sensor comprehensive screening system can screen 1-48 (expandable to 350) or more pressure sensors at one time according to customer needs
    2. Humanized design of operation interface, fully realizing manual, automatic and free switching
    3. Secondary development of software functions based on customer needs can fully meet each customer's requirements for software functions.
    4 It has the ability to automatically collect, process, store data, and print test reports in a specified format.
    5.  Data storage: Test data is exported, saved, and printed through a USB serial port.
    System composition The system is composed of console, pressure control system, pressure connection port, software, data collector, computer, printer, etc. Note: the pressure control system adopts sensor pressure controller or Hsin series pressure control system.
    Measuring range (-0.1~21)MPa;(-0.1~40)MPa;(0~70)MPa; (the medium is air) (select the range according to the demand)
    Sensor accuracy 0.008%I.S; 0.01%I.S; 0.02%I.S; 0.01%F.S; 0.02%F.S; 0.05%F.S
    weight About 80kg
    Test volume 50 ~1,000 ccm
    Control 0 ~100 % FS
    Pressure control volatility <0.003%F.S
    Control speed <15 second
    power supply AC220V
    work environment (-10~40 )℃; <90% RH
    Implementation procedures and specifications ●JJG 860-2015 Verification regulation of pressure sensor (static);
    ●JJG 882-2004 verification regulation of pressure transmitter;
    ●JJG544-2011Verification regulation of pressure controller;
    ●GJB4409A-2011General specification for pressure sensors
    ●TSG R0003-2007Supervision Regulation on safety technology of simple pressure vessels
     ●TSG ZF001-2006 Supervision Regulation on safety technology of safety valves
    ●GB4208-84classification of shell protection grade
    ●GB3096-2008Acoustic environment quality standard
    ●GB/T12985General rule of applying percentile of human body size in product design
    ●GB/T14775 General Ergonomic requirements for Manipulators
    ●GJB-Z102Software reliability and safety design criteria
    Strains 6800 (3)sejStrains 6800 (4)8f1

    Range Selection Table of Pressure Sensor

    Range selection table of 0.01% F.S pressure sensor
    measuring range (-0.1~21)MPa (-0.1~40)MPa (0~70)MPa
    Gauge pressure 0~2.5kPa to 0~21MPa 0~7kPa to 0~40MPa 0~10MPa to 0~70MPa
    positive negative pressure -1.25~1.25kPa to -0.1~21MPa -3.5~3.5kPa to -0.1~40MPa /
    absolute pressure 0~50kPa to 0~21.1MPa abs 0~52kPa to 0~40.1MPa 0~10.1MPa to 0~70.1MPa
    Range selection of 0.01% i.s-50 pressure sensor
    measuring range (-0.1~21)MPa (-0.1~40)MPa (0~70)MPa
    Gauge pressure 0~0.1MPa to 0~21MPa 0~0.1MPa to 0~40MPa 0~10MPa to 0~40MPa
    positive negative pressure -0.1~1MPa to -0.1~21MPa -0.1~1MPa to -0.1~40MPa /
    absolute pressure 0~0.1MPa to 0~21.1MPa abs 0~0.1MPa to 0~40.1MPa 0~10.1MPa to 0~40.1MPa